Model |
SCN-1200-05 |
SCN-1200-12 |
SCN-1200-15 |
SCN-1200-24 |
SCN-1200-48 |
|
DC output voltage |
5V |
12V |
15V |
24V |
48V |
Output |
Output voltage tolerance |
±2.5% |
±1% |
±1% |
±1% |
±1% |
|
Rated output current |
180A |
100A |
80A |
50A |
25A |
|
Output current range |
0-180A |
0-100A |
0-80A |
0-50A |
0-25A |
|
Output power |
900W |
1200W |
1200W |
1200W |
1200W |
|
Ripple and the noise |
100mVp-p |
120mVp-p |
150mVp-p |
240mVp-p |
480mVp-p |
|
Dc voltage adjustable scope |
+ 5%; By external 2 ~ 5 V voltage control, which can adjust the output voltage of the rated voltage of the in the range of 40% ~ 100% in value |
|
Start, rise, keep time |
800ms, 50ms, 16ms Loaded with |
Intput |
Input voltage range |
200~260 VAC47~63 Hz; 290~370VDC |
Exchange input current |
11A/230VAC |
efficiency |
85% |
88% |
89% |
91% |
93% |
Impulse current |
120A230V |
Leakage current |
3.5 mA/240VAC |
Protection characteristics |
Overload protection |
101%~115% |
110%~135% |
Protection way: current limiting, delay shut off, restart |
Overvoltage protection |
110%~135% |
Protection way: cut output, restart |
High temperature protection |
TSW1 (power tube) temperature > 100 ºC, restart when cut off output |
Environment |
Working temperature, humidity |
-10ºC~+65ºC,20%~90 %RH |
Keep temperature, humidity |
-20ºC~+85ºC,10%~95 %RH |
Vibrate resistance |
10 ~ 200 Hz ac, 2 G 10 min. / 1 cycle time, 60 minutes, the axis |
Security |
Compression sex |
I/P-O/P, I/P-FG:1500VAC |
Insulation resistance |
I/P-O/P, I/P-FG, >100M Ohms / 500VDC |
Standards |
Safety standards |
Accord with |
UL1950,CSA22.2,IEC60950 |
EMC standard |
Accord with |
FCC Part 15 Class A |
Other |
Weight |
4.7Kg; |
Packaging |
4pcs/20.2kg/CARTON |
Note |
1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ºC conditions measuring income value. |
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it's EMC index. |