ELCB, Earthleakage Circuit Breaker, Magnetic Circuit Breaker manufacturer / supplier in China, offering Earthleakage Circuit Breaker (ELCB) of Dz15L-100-4901 63amagnetic Circuit Breaker, NPN PNP Type Inductive Proximity Sensor Switch Waterproof Light Rod, 3 Phase 220V Coil AC Contactor and so on.

Gold Member Since 2017
Audited Supplier
Supplier Homepage Products Earthleakage Circuit Breaker (ELCB) of Dz15L-100-4901 63amagnetic Circuit Breaker

Earthleakage Circuit Breaker (ELCB) of Dz15L-100-4901 63amagnetic Circuit Breaker

You Might Also Like


Basic Info

Model NO.: DZ15L
Poles Number: 4
Type: Circuit Breaker
Function: Magnetic Circuit Breaker
Certification: CE, CCC
Trademark: FUNELEC
Specification: CCC, CE
Origin: China
HS Code: 85362000

Product Description

Product Description
DZ15LE series intelligent type earthleakage circuit breaker, is applied to distribution power-net of frequency 50Hz, Rated operate voltage 220V or 380V, Rated current up to 100A. And it provides indirect protection, it is also used to prevent the fire dange which cause by grounding fault becasue of equipment insolation damage.
And it is applied to distribute electric power and protect circuit band power-supply device against overload and short-circuit, and it also works for circuit unfrequently transfering and motor unfrequently starting.
This production conforms to the standard of IEC60947-2 and GB14048.2.
Normal operational conditions and installation conditions
3.1 Temperature: No higher than +40º C, and no lower than -5º C, and the day average temperature no higher than +35º C.
3.2 Altitude: No higher than 2000m
3.3 The relative humidity: No more than 50%, when temperature is +40º C. The product can withstand higher humidity under lower temperature, for instance, when it at +20º C, the production can withstand 90% relative humidity.
The condensation that happened because of temperature changes should be taken care.
And Installation location should have no exploresion danger, and no gas and conductive dust which can cause corrosion and insulation damage.
3.4 Class of pollution: 3 Calss
3.5 Maximum install inclined angle: 5° , it should be installed at the place without obvious impact and weather-influence. Upper terminal for power-supply side, Lower terminal for loading side.
3.6 Installation type: III
3.7 Installation electromagnetic environment: B type
3.8 External magneticfield of installation location should be exceed than 5 times of earth magnetic field.
For more details and information, please contact us with no hesitate